Do you need a spare part?

eONE Family & BLM Kit

Image

Product Code

Description

Compatibility

002838 - BLM cuvette MM

002838

BLM Cuvette MM

Cuvette made of 2 Delrin compartments of 1 ml each (max 700 ul volume), including inox screws and Allen key (002806). Suitable for the Montal Mueller technique.

BLM Kit

000698

000698

BLM Cuvette

Cuvette made of 2 Delrin compartments of 1ml each (max 700ul volume), including two gaskets and inox screws. ** Purchasable only as a replacement for the same item already in the customer’s possession

BLM Kit

002843

002843

Septum Polyimide Ø 50 μm hole for Montal Muller technique

Polyimide septum for BLM cuvette MM 25 μm thickness. Compatible only with item code 002838

BLM Kit

002844

002844

Septum Polyimide Ø 75 μm hole for Montal Muller technique

Polyimide septum for BLM cuvette MM 25 μm thickness. Compatible only with item code 002838

BLM Kit

002839

002839

Septum Polyimide Ø 100 μm hole for Montal Muller technique

Polyimide septum for BLM cuvette MM 25 μm thickness. Compatible only with item code 002838

BLM Kit

002841

002841

Septum Polyimide Ø 150 μm hole for Montal Muller technique

Polyimide septum for BLM cuvette MM 25 μm thickness. Compatible only with item code 002838

BLM Kit

002842

002842

Septum Polyimide Ø 200 μm hole for Montal Muller technique

Polyimide septum for BLM cuvette MM 25 μm thickness. Compatible only with item code 002838

BLM Kit

002903

002903

Septum Teflon Ø 50 μm for Montal Muller technique

Teflon septum for BLM cuvette MM 50 μm thickness. Compatible only with item code 002838

BLM Kit

002904

002904

Septum Teflon Ø 80 μm for Montal Muller technique

Teflon septum for BLM cuvette MM 50 μm thickness. Compatible only with item code 002838

BLM Kit

002905

002905

Septum Teflon Ø 100 μm for Montal Muller technique

Teflon septum for BLM cuvette MM 50 μm thickness. Compatible only with item code 002838

BLM Kit

002212

002212

Septum Teflon Ø 50 μm hole

Teflon septum for BLM cuvette 50 μm thickness. Compatible only with item code 000698. Purchasable by customers already in possession of BLM Cuvette item code 000698.

BLM Kit

002213

002213

Septum Teflon Ø 80 μm hole

Teflon septum for BLM cuvette 50 μm thickness. Compatible only with item code 000698. Purchasable by customers already in possession of BLM Cuvette item code 000698.

BLM Kit

002212

002214

Septum Teflon Ø 110 μm hole

Teflon septum for BLM cuvette 50 μm thickness. Compatible only with item code 000698. Purchasable by customers already in possession of BLM Cuvette item code 000698.

BLM Kit

001064

001064

Septum Polyimide Ø 100 µm hole

Polyimide septum for BLM cuvette 50 µm thickness. Compatible only with item code 000698. Purchasable by customers already in possession of BLM Cuvette item code 000698.

BLM Kit

001065

001065

Septum Polyimide Ø 150 µm hole

Polyimide septum for BLM cuvette 50 µm thickness. Compatible only with item code 000698. Purchasable by customers already in possession of BLM Cuvette item code 000698.

BLM Kit

001066

001066

Septum Polyimide Ø 200 µm hole

Polyimide septum for BLM cuvette 50 µm thickness. Compatible only with item code 000698. Purchasable by customers already in possession of BLM Cuvette item code 000698.

BLM Kit

000694

000694

Faraday cage for BLM kit 

Faraday cage made of Aluminium with flip-up opening, size 160x100x50 mm, white painted

BLM Kit

003718

003718

Holder eONE for BLM kit (Gen 2)

Compatible with eONE devices Gen2 (003703, 003704, 003705, 003706)

BLM Kit

000688

000688

Holder eONE for BLM kit (Gen 1)

**Purchasable only as an accessory of eONE devices Gen1 (001871, 001872, 001873, 002909) already owned by the customer.

BLM Kit

000498

000498

Paintbrush – for BLM painting

BLM Kit

003199

003199

eONE input connector wires – electrode adaptors form 1 mm plug to Ø 0.5 mm socket (n. 2 pcs). Compatible with eONE devices Gen 2

BLM Kit

000635

000635

SMB electrodes adaptor – for Ø 0.5 mm electrodes

BLM Kit

001153

001153

SMB and 1 mm pin adaptor – for Ø 0.5 mm electrodes

BLM Kit

Nanopore Reader 100 kHz

Image

Product Code

Description

Compatibility

001417

001417

BLM chip Ø 100 μm hole

BLM flow cell with horizontal Polyimide septum with Ø 100 μm hole, 12.5 μm thickness, with embedded Ag electrodes (unchlorinated), designed for lipid bilayer experiments with the pseudo-bubble or painting method. Min Order quantity 3.

Nanopore Reader 100 kHz

001417

001418

BLM chip Ø 150 μm hole

BLM flow cell with horizontal Polyimide septum with Ø 150 μm hole, 12.5 μm thickness, with embedded Ag electrodes (unchlorinated), designed for lipid bilayer experiments with the pseudo-bubble or painting method. Min Order quantity 3.

Nanopore Reader 100 kHz

003811

003811

BLMchip_MM Ø 50 μm hole (Gen 2)

BLM flow cell with vertical Polyimide septum, made by PMMA, designed for the Montal-Mueller technique. Polyimide septum Ø 50 µm hole, 25 µm thickness. Chlorinated wires.

Nanopore Reader 100 kHz

003812

003812

BLMchip_MM Ø 75 μm hole (Gen 2)

BLM flow cell with vertical Polyimide septum, made by PMMA, designed for the Montal-Mueller technique. Polyimide septum Ø 75 µm hole, 25 µm thickness. Chlorinated wires.

Nanopore Reader 100 kHz

003743

003743

BLMchip_MM Ø 100 μm hole (Gen 2)

BLM flow cell with vertical Polyimide septum, made by PMMA, designed for the Montal-Mueller technique. Polyimide septum Ø 100 µm hole, 25 µm thickness. Chlorinated wires.

Nanopore Reader 100 kHz

001517

001517

PCB for Nanopore Reader – 3 pins PCB

3 Ag wires required for connection, Ø 0.5 mm (not provided). For general purpose use.

Nanopore Reader 100 kHz

Nanopore Reader HC & 10 MHz

Image

Product Code

Description

Compatibility

002848

002848

Nanopore flow cell PMMA 4×4 & 5×5- 1.0

Reusable PMMA flow cell for solid state nanopores, suitable for 4×4 and 5×5 mm squared nanopore chip with a thickness range between 200 µm and 300 µm (chip is not provided), including n.6 silicon gaskets. Silver wires are already chlorinated.

Nanopore Reader HC & 10 MHz

003216

003216

Nanopore flow cell PMMA 4×4 & 5×5- 1.2

Reusable PMMA flow cell for solid state nanopores, suitable for 4×4 and 5×5 mm squared nanopore chip with a thickness range between 400 µm and 500 µm (chip is not provided), including n.6 silicon gaskets. Silver wires are already chlorinated.

Nanopore Reader HC & 10 MHz

003217

003217

Nanopore flow cell PMMA 4×4 & 5×5- 1.4

Reusable PMMA flow cell for solid state nanopores, suitable for 4×4 and 5×5 mm squared nanopore chip with a thickness range between 400 µm and 500 µm (chip is not provided), including n.6 silicon gaskets. Silver wires are already chlorinated.

Nanopore Reader HC & 10 MHz

003523

003523

Nanopore flow cell PTFE 4×4 & 5×5 – 1.0

Reusable PTFE flow cell for solid state nanopores, suitable for 4×4 and 5×5 mm squared nanopore chip with a thickness range between 200 µm and 300 µm (chip is not provided), including n.6 silicon gaskets. Silver wires are already chlorinated.

Nanopore Reader HC & 10 MHz

003524

003524

Nanopore flow cell PTFE 4×4 & 5×5 – 1.2

Reusable PTFE flow cell for solid state nanopores, suitable for 4×4 and 5×5 mm squared nanopore chip with a thickness range between 200 µm and 300 µm (chip is not provided), including n.6 silicon gaskets. Silver wires are already chlorinated.

Nanopore Reader HC & 10 MHz

003525

003525

Nanopore flow cell PTFE 4×4 & 5×5 – 1.4

Reusable PTFE flow cell for solid state nanopores, suitable for 4×4 and 5×5 mm squared nanopore chip with a thickness range between 200 µm and 300 µm (chip is not provided), including n.6 silicon gaskets. Silver wires are already chlorinated.

Nanopore Reader HC & 10 MHz

003126

003126

Nanopore flow cell PMMA Ø 3 mm – 1.0

Reusable PMMA flow cell for 3 mm round nanopore chip of 200 µm thickness (chip is not provided), including n. 6 circular silicon gaskets.

Nanopore Reader HC & 10 MHz

002996

002996

Gasket kit for nanopore flow cell 4×4 & 5×5

Silicon gaskets for 4x4mm and 5x5mm (bundle of 10 pcs.)

Nanopore Reader HC & 10 MHz

002994

002994

Disposable flow cell for non-standard Nanopore chips

Disposable horizontal PMMA nanopore flow cell with 3M double side tape for 5×5 mm squared nanopore chip, various thicknesses

Nanopore Reader HC

002995

002995

Disposable flow cell for non-standard Nanopore chips – 5x

Disposable horizontal PMMA nanopore flow cell with 3M double side tape for 5×5 mm squared nanopore chip, various thicknesses

Nanopore Reader HC

002286

002286

PCB low noise for nanopore flow cell

Replacement PCB (low noise version) for solid state nanopore flow cells 002848 – 003216 – 003217 – 003523 – 003524 – 003525 – 003126. Ag wires required for connection 20 mm long, Ø 0.5 mm (not provided).

Nanopore Reader HC & 10 MHz

002287

002287

PCB ultra low noise for nanopore flow cell

Replacement PCB (ultra low noise version) for solid state nanopore flow cells 002848 – 003216 – 003217 – 003523 – 003524 – 003525 – 003126. Ag wires required for connection 20 mm long, Ø 0.5 mm (not provided).

Nanopore Reader HC & 10 MHz

ePatch

Image

Product Code

Description

Compatibility

000819

000819

Pipette holder – for Ø 1.5 mm glass capillaries, SMA connector. Silver wires unchlorinated.

ePatch

000911

000911

ePatch Model Cell – including pin to pin wire for reference connection

ePatch

002106

002106

ePatch mounting adaptor – Dovetail

ePatch

002107

002107

ePatch mounting adaptor – Rodbar

ePatch

000928

000928

Bath reference pin wire ePatch  – with unchlorinated Ag wire Ø 0.5 mm

ePatch

001222

001222

Digital I/O cable – MMCX to SMA, 75 cm long

ePatch

001154

001154

SMA and 1 mm pin adaptor – for Ø 0.5 mm electrodes

Multichannel Amplifiers

Image

Product Code

Description

Compatibility

003439

003439

Nanopore flow cell array 4 ch PMMA 4×4 – 1.0 mm

Array of 4 nanopore flow cells PMMA for 4×4 mm squared nanopore chip with a thickness range between 200 μm and 300 μm (chip is not provided), including n. 12 gaskets. Chamber thickness 1.0 mm.

Nanopore Reader 4×10 MHz

003974

003974

Nanopore flow cell array 4 ch PMMA 4×4 – 1.3 mm

Array of 4 nanopore flow cells PMMA for 4×4 mm squared nanopore chip with a thickness range between 200 μm and 300 μm (chip is not provided), including n. 12 gaskets. Chamber thickness 1.3 mm.

Nanopore Reader 4×10 MHz

003975

003975

Nanopore flow cell array 4 ch PMMA 4×4 – 1.6 mm

Array of 4 nanopore flow cells PMMA for 4×4 mm squared nanopore chip with a thickness range between 200 μm and 300 μm (chip is not provided), including n. 12 gaskets. Chamber thickness 1.6 mm.

Nanopore Reader 4×10 MHz

003171

003171

Nanopore flow cell array 4 ch PMMA 4×4 & 5×5 – 1.0 mm

Array of 4 nanopore flow cells PMMA for 5×5 and 4×4 mm squared nanopores with thickness between 200 μm to 300 μm, including n. 12 gaskets. Chamber thickness 1.0 mm.

e4

001651

001651

Connection board kit e4 – for electrodes Ø 0.5 mm

e4

002746

002746

Nanopore flow cell array 16 ch PMMA 4×4 – 1.0 mm

Array of 16 nanopore flow cells PMMA for 4×4 mm squared nanopores with thickness between 200 μm to 300 μm, including n. 48 gaskets. Chamber thickness 1.0 mm.

e16HC

002747

002747

Nanopore flow cell array 16 ch PMMA 4×4 – 1.1 mm

Array of 16 nanopore flow cells PMMA for 4×4 mm squared nanopores with thickness between 300 μm to 400 μm, including n. 48 gaskets. Chamber thickness 1.1 mm.

e16HC

002748

002750

Nanopore flow cell array 16 ch PMMA 4×4 – 1.2 mm

Array of 16 nanopore flow cells PMMA for 4×4 mm squared nanopores with thickness between 500 μm to 600 μm, including n. 48 gaskets. Chamber thickness 1.2 mm.

e16HC

002748

002748

Nanopore flow cell array 16 ch PMMA 4×4 – 1.3 mm

Array of 16 nanopore flow cells PMMA for 4×4 mm squared nanopores with thickness between 500 μm to 600 μm, including n. 48 gaskets. Chamber thickness 1.3 mm.

e16HC

002749

002749

Nanopore flow cell array 16 ch PMMA 4×4 – 1.4 mm

Array of 16 nanopore flow cells PMMA for 4×4 mm squared nanopores with thickness between 500 μm to 600 μm, including n. 48 gaskets. Chamber thickness 1.4 mm.

e16HC

More spare parts

Image

Product Code

Description

Compatibility

000927

000927

GND cable – with clip and 2mm banana plug, 70cm long

002275

002275

Power supply adaptor 5Vdc – Please select AC plug among: EU, UK, US, AUS

002754

002754

Power supply low noise adaptor 5Vdc – Please select AC plug among: EU, UK, US, AUS

Nanopore Reader 10 MHz and 4×10 MHz

001751

001751

RJ45 cable – double shielded, 50 cm long

000499

000499

Ag wires – Unchlorinated silver wires 40 mm long – Ø 0.5 mm (n. 2 pcs)

001264

001264

SMA male to BNC female adaptor

000049

000049

SMA male to BNC male adaptor

002363

002363

SMA to MMCX Coaxial Cable – RG-316 coaxial cable, 1.0 m length

003040

003040

USB-C cable 1m

001632

001632

USB cable 1m

001846

001846

USB cable 1.8m