Image
Do you need a spare part?
eONE Family & BLM Kit
Product Code
Description
Compatibility
002838
BLM Cuvette MM
Cuvette made of 2 Delrin compartments of 1 ml each (max 700 ul volume), including inox screws and Allen key (002806). Suitable for the Montal Mueller technique.
BLM Kit
000698
BLM Cuvette
Cuvette made of 2 Delrin compartments of 1ml each (max 700ul volume), including two gaskets and inox screws. ** Purchasable only as a replacement for the same item already in the customer’s possession
BLM Kit
002843
Septum Polyimide Ø 50 μm hole for Montal Muller technique
Polyimide septum for BLM cuvette MM 25 μm thickness. Compatible only with item code 002838
BLM Kit
002844
Septum Polyimide Ø 75 μm hole for Montal Muller technique
Polyimide septum for BLM cuvette MM 25 μm thickness. Compatible only with item code 002838
BLM Kit
002839
Septum Polyimide Ø 100 μm hole for Montal Muller technique
Polyimide septum for BLM cuvette MM 25 μm thickness. Compatible only with item code 002838
BLM Kit
002841
Septum Polyimide Ø 150 μm hole for Montal Muller technique
Polyimide septum for BLM cuvette MM 25 μm thickness. Compatible only with item code 002838
BLM Kit
002842
Septum Polyimide Ø 200 μm hole for Montal Muller technique
Polyimide septum for BLM cuvette MM 25 μm thickness. Compatible only with item code 002838
BLM Kit
002903
Septum Teflon Ø 50 μm for Montal Muller technique
Teflon septum for BLM cuvette MM 50 μm thickness. Compatible only with item code 002838
BLM Kit
002904
Septum Teflon Ø 80 μm for Montal Muller technique
Teflon septum for BLM cuvette MM 50 μm thickness. Compatible only with item code 002838
BLM Kit
002905
Septum Teflon Ø 100 μm for Montal Muller technique
Teflon septum for BLM cuvette MM 50 μm thickness. Compatible only with item code 002838
BLM Kit
002212
Septum Teflon Ø 50 μm hole
Teflon septum for BLM cuvette 50 μm thickness. Compatible only with item code 000698. Purchasable by customers already in possession of BLM Cuvette item code 000698.
BLM Kit
002213
Septum Teflon Ø 80 μm hole
Teflon septum for BLM cuvette 50 μm thickness. Compatible only with item code 000698. Purchasable by customers already in possession of BLM Cuvette item code 000698.
BLM Kit
002214
Septum Teflon Ø 110 μm hole
Teflon septum for BLM cuvette 50 μm thickness. Compatible only with item code 000698. Purchasable by customers already in possession of BLM Cuvette item code 000698.
BLM Kit
001064
Septum Polyimide Ø 100 µm hole
Polyimide septum for BLM cuvette 50 µm thickness. Compatible only with item code 000698. Purchasable by customers already in possession of BLM Cuvette item code 000698.
BLM Kit
001065
Septum Polyimide Ø 150 µm hole
Polyimide septum for BLM cuvette 50 µm thickness. Compatible only with item code 000698. Purchasable by customers already in possession of BLM Cuvette item code 000698.
BLM Kit
001066
Septum Polyimide Ø 200 µm hole
Polyimide septum for BLM cuvette 50 µm thickness. Compatible only with item code 000698. Purchasable by customers already in possession of BLM Cuvette item code 000698.
BLM Kit
000694
Faraday cage for BLM kit
Faraday cage made of Aluminium with flip-up opening, size 160x100x50 mm, white painted
BLM Kit
003718
Holder eONE for BLM kit (Gen 2)
Compatible with eONE devices Gen2 (003703, 003704, 003705, 003706)
BLM Kit
000688
Holder eONE for BLM kit (Gen 1)
**Purchasable only as an accessory of eONE devices Gen1 (001871, 001872, 001873, 002909) already owned by the customer.
BLM Kit
003199
eONE input connector wires – electrode adaptors form 1 mm plug to Ø 0.5 mm socket (n. 2 pcs). Compatible with eONE devices Gen 2
BLM Kit
Nanopore Reader 100 kHz
Image
Product Code
Description
Compatibility
001417
BLM chip Ø 100 μm hole
BLM flow cell with horizontal Polyimide septum with Ø 100 μm hole, 12.5 μm thickness, with embedded Ag electrodes (unchlorinated), designed for lipid bilayer experiments with the pseudo-bubble or painting method. Min Order quantity 3.
Nanopore Reader 100 kHz
001418
BLM chip Ø 150 μm hole
BLM flow cell with horizontal Polyimide septum with Ø 150 μm hole, 12.5 μm thickness, with embedded Ag electrodes (unchlorinated), designed for lipid bilayer experiments with the pseudo-bubble or painting method. Min Order quantity 3.
Nanopore Reader 100 kHz
003811
BLMchip_MM Ø 50 μm hole (Gen 2)
BLM flow cell with vertical Polyimide septum, made by PMMA, designed for the Montal-Mueller technique. Polyimide septum Ø 50 µm hole, 25 µm thickness. Chlorinated wires.
Nanopore Reader 100 kHz
003812
BLMchip_MM Ø 75 μm hole (Gen 2)
BLM flow cell with vertical Polyimide septum, made by PMMA, designed for the Montal-Mueller technique. Polyimide septum Ø 75 µm hole, 25 µm thickness. Chlorinated wires.
Nanopore Reader 100 kHz
003743
BLMchip_MM Ø 100 μm hole (Gen 2)
BLM flow cell with vertical Polyimide septum, made by PMMA, designed for the Montal-Mueller technique. Polyimide septum Ø 100 µm hole, 25 µm thickness. Chlorinated wires.
Nanopore Reader 100 kHz
Nanopore Reader HC & 10 MHz
Image
Product Code
Description
Compatibility
002848
Nanopore flow cell PMMA 4×4 & 5×5- 1.0
Reusable PMMA flow cell for solid state nanopores, suitable for 4×4 and 5×5 mm squared nanopore chip with a thickness range between 200 µm and 300 µm (chip is not provided), including n.6 silicon gaskets. Silver wires are already chlorinated.
Nanopore Reader HC & 10 MHz
003216
Nanopore flow cell PMMA 4×4 & 5×5- 1.2
Reusable PMMA flow cell for solid state nanopores, suitable for 4×4 and 5×5 mm squared nanopore chip with a thickness range between 400 µm and 500 µm (chip is not provided), including n.6 silicon gaskets. Silver wires are already chlorinated.
Nanopore Reader HC & 10 MHz
003217
Nanopore flow cell PMMA 4×4 & 5×5- 1.4
Reusable PMMA flow cell for solid state nanopores, suitable for 4×4 and 5×5 mm squared nanopore chip with a thickness range between 400 µm and 500 µm (chip is not provided), including n.6 silicon gaskets. Silver wires are already chlorinated.
Nanopore Reader HC & 10 MHz
003523
Nanopore flow cell PTFE 4×4 & 5×5 – 1.0
Reusable PTFE flow cell for solid state nanopores, suitable for 4×4 and 5×5 mm squared nanopore chip with a thickness range between 200 µm and 300 µm (chip is not provided), including n.6 silicon gaskets. Silver wires are already chlorinated.
Nanopore Reader HC & 10 MHz
003524
Nanopore flow cell PTFE 4×4 & 5×5 – 1.2
Reusable PTFE flow cell for solid state nanopores, suitable for 4×4 and 5×5 mm squared nanopore chip with a thickness range between 200 µm and 300 µm (chip is not provided), including n.6 silicon gaskets. Silver wires are already chlorinated.
Nanopore Reader HC & 10 MHz
003525
Nanopore flow cell PTFE 4×4 & 5×5 – 1.4
Reusable PTFE flow cell for solid state nanopores, suitable for 4×4 and 5×5 mm squared nanopore chip with a thickness range between 200 µm and 300 µm (chip is not provided), including n.6 silicon gaskets. Silver wires are already chlorinated.
Nanopore Reader HC & 10 MHz
003126
Nanopore flow cell PMMA Ø 3 mm – 1.0
Reusable PMMA flow cell for 3 mm round nanopore chip of 200 µm thickness (chip is not provided), including n. 6 circular silicon gaskets.
Nanopore Reader HC & 10 MHz
002996
Gasket kit for nanopore flow cell 4×4 & 5×5
Silicon gaskets for 4x4mm and 5x5mm (bundle of 10 pcs.)
Nanopore Reader HC & 10 MHz
002994
Disposable flow cell for non-standard Nanopore chips
Disposable horizontal PMMA nanopore flow cell with 3M double side tape for 5×5 mm squared nanopore chip, various thicknesses
Nanopore Reader HC
002995
Disposable flow cell for non-standard Nanopore chips – 5x
Disposable horizontal PMMA nanopore flow cell with 3M double side tape for 5×5 mm squared nanopore chip, various thicknesses
Nanopore Reader HC
002286
PCB low noise for nanopore flow cell
Replacement PCB (low noise version) for solid state nanopore flow cells 002848 – 003216 – 003217 – 003523 – 003524 – 003525 – 003126. Ag wires required for connection 20 mm long, Ø 0.5 mm (not provided).
Nanopore Reader HC & 10 MHz
ePatch
Image
Product Code
Description
Compatibility
000819
Pipette holder – for Ø 1.5 mm glass capillaries, SMA connector. Silver wires unchlorinated.
ePatch
Multichannel Amplifiers
Image
Product Code
Description
Compatibility
003439
Nanopore flow cell array 4 ch PMMA 4×4 – 1.0 mm
Array of 4 nanopore flow cells PMMA for 4×4 mm squared nanopore chip with a thickness range between 200 μm and 300 μm (chip is not provided), including n. 12 gaskets. Chamber thickness 1.0 mm.
Nanopore Reader 4×10 MHz
003974
Nanopore flow cell array 4 ch PMMA 4×4 – 1.3 mm
Array of 4 nanopore flow cells PMMA for 4×4 mm squared nanopore chip with a thickness range between 200 μm and 300 μm (chip is not provided), including n. 12 gaskets. Chamber thickness 1.3 mm.
Nanopore Reader 4×10 MHz
003975
Nanopore flow cell array 4 ch PMMA 4×4 – 1.6 mm
Array of 4 nanopore flow cells PMMA for 4×4 mm squared nanopore chip with a thickness range between 200 μm and 300 μm (chip is not provided), including n. 12 gaskets. Chamber thickness 1.6 mm.
Nanopore Reader 4×10 MHz
003171
Nanopore flow cell array 4 ch PMMA 4×4 & 5×5 – 1.0 mm
Array of 4 nanopore flow cells PMMA for 5×5 and 4×4 mm squared nanopores with thickness between 200 μm to 300 μm, including n. 12 gaskets. Chamber thickness 1.0 mm.
e4
002746
Nanopore flow cell array 16 ch PMMA 4×4 – 1.0 mm
Array of 16 nanopore flow cells PMMA for 4×4 mm squared nanopores with thickness between 200 μm to 300 μm, including n. 48 gaskets. Chamber thickness 1.0 mm.
e16HC
002747
Nanopore flow cell array 16 ch PMMA 4×4 – 1.1 mm
Array of 16 nanopore flow cells PMMA for 4×4 mm squared nanopores with thickness between 300 μm to 400 μm, including n. 48 gaskets. Chamber thickness 1.1 mm.
e16HC
002750
Nanopore flow cell array 16 ch PMMA 4×4 – 1.2 mm
Array of 16 nanopore flow cells PMMA for 4×4 mm squared nanopores with thickness between 500 μm to 600 μm, including n. 48 gaskets. Chamber thickness 1.2 mm.
e16HC
002748
Nanopore flow cell array 16 ch PMMA 4×4 – 1.3 mm
Array of 16 nanopore flow cells PMMA for 4×4 mm squared nanopores with thickness between 500 μm to 600 μm, including n. 48 gaskets. Chamber thickness 1.3 mm.
e16HC
More spare parts
Image
Product Code
Description
Compatibility
002754
Power supply low noise adaptor 5Vdc – Please select AC plug among: EU, UK, US, AUS